P/N 18589K (07/14) Made in U.S.A. OUTDOOR GAS INFRARED PATIO HEATER INSTALLATION, OPERATION, & MAINTENANCE MANUA
professional must be consulted when heaters are installed where fire sprinklers are present to ensure that heaters and the fire sprinkler system are
7. PATIO DESIGN CONSIDERATION Heater placement is critical for effective and efficient patio heating. If heaters are placed too close together or m
8. GAS INLET The gas inlet of the heater is located on the left side of the unit by design. The heater is NOT to be mounted to where the ga
MOUNTING CLEARANCES – GAS INFRARED HEATER Each heater must be installed such that the following “Minimum Clearance to Combustibles’ are maintained.
12 Flexible Gas Line or Hard Plumbing AC/DC Adapter (OPTIONAL) (Usage is optional) * Do
ELECTRICAL INSTRUCTIONS – GAS INFRARED HEATER The receiver is powered by four 1.5V AA batteries located in a battery pack ins
OPERATING INSTRUCTIONS – GAS INFRARED HEATER A) INITIAL START-UP 1) Before you start your heater examine the heater installation to determine that:
3. Check for gas leaks using soapy water at all gas connections and joint unions. NEVER use a flame to check for leaks 4. Pilot Burner Ignitio
the heater will not light after 3 attempts, shutoff the heater, shut-off the heater’s manual gas inlet valve and call your qualified service agency
PREVENTIVE MAINTENANCE – GAS INFRARED HEATER Routine maintenance should be performed at least once a year by a qualified service agency to insure
A special message… Congratulations on your purchase of TWIN EAGLES outdoor gas infrared heater. We have designed this heater to provide you and y
TROUBLESHOOTING GUIDE – GAS INFRARED HEATER NEVER attempt to service the heater without disconnecting or shutting OFF its power and gas supply from
Heater valve will not switch from Hi to Low and vice versa 1. Low battery pack. Replace 4 AA batteries. 2. Ground wire not connected. Connect gro
REPLACEMENT PARTS LIST – GAS INFRARED HEATER 20 1 2 3 A 6a 7 8 9 10 11 12 13 14 15
REPLACEMENT PARTS LIST – GAS INFRARED HEATER Item Number Part Number Part Description Qty 1 S13351 Infrared Burner 1 2 S21916-4Y Heat Diffuser Frame
TWIN EAGLES OUTDOOR GAS INFRARED HEATER Limited Product Warranty ONE-YEAR RESIDENTIAL WARRANTY: Twin Eagles warrants the outdoor gas heater to b
Customer Service ATTN: Warranty Department 13231 East 166th Street Cerritos, CA 90703 Fax no. (562) 802-3391 Warranty R
SAFETY PRECAUTIONS – GAS INFRARED HEATER 1 Never block the front grille of the heater. The heater
TABLE OF CONTENTS – GAS INFRARED HEATER Safety Precautions…………………………………………………………………………..……. 1 TWIN EAGLES GAS INFRARED HEATER features..………………………
TWIN EAGLES – GAS INFRARED HEATER FEATURES TWIN EAGLES Gas Infrared Heater extends the outdoor activities during the cool days of fall and through
GAS INSTALLATION REQUIREMENTS – GAS INFRARED HEATER Each patio heater is set and tested at the factory for the type of gas supply to be used. Identi
d) Installation of a drip leg in the gas supply line going to each heater is required to minimize the possibility of any loose scale or dirt within
LEAK TEST PROCEDURE CAUTION BEFORE TESTING Finding and/or fixing a gas leak is NOT a “DO-IT-YOURSELF” procedure. NEVER USE THE PATIO HEATER WI
SELECTING MOUNTING LOCATION – GAS INFRARED HEATER When selecting a location to install the TWIN EAGLES Gas Infrared Heater, all the following fact